Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →For Blackheath buildings, we supply, replace and check fire-rated curtain walling wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.
Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We cover Blackheath and the surrounding postcode districts, including SE3, SE13, SE10, SE12, SE8, SE7. Nearby towns we also serve include Greenwich, Catford, Eltham. Blackheath is one of the Greater London districts we cover.
Every quote in Blackheath identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Blackheath around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Fire-rated curtain walling applies to many building types in Blackheath, including student accommodation and healthcare buildings.
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.
Survey timing in Blackheath depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Blackheath and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.