Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →For Ely buildings, we supply, replace and check fire-rated curtain walling wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
After survey you get a fixed written quote for the agreed scope, so Ely budgets are not open-ended.
Every quote in Ely identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Ely around residents, staff or pupils, with out-of-hours options.
External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.
In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
Our Cambridgeshire coverage takes in Ely (CB7, CB6) and the neighbouring towns of Newmarket, March, Cambridge. Ely is about 40 km from Peterborough, the largest town in our Cambridgeshire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-rated curtain walling applies to many building types in Ely, including blocks of flats and schools and colleges.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
Building work in Ely follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Ely and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.