Fire-rated curtain walling across Bristol covers 13 postcode districts in the BS postcode areas. Every job is built around a tested system.

E 30 – EI 60EnglandBS

Quote for Bristol

Tell us what you need. We reply with next steps and a guide price.

Towns we cover in Bristol

Our Bristol coverage spans 13 postcode districts across the BS postcode areas.

What our fire-rated curtain walling service includes in Bristol

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Tested fire-rated curtain wall systems
  • Slab-edge fire-stopping and cavity barriers to the design
  • External-grade fire glass

Before you order in Bristol

Higher-risk buildings

Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.

Combustibility rules

In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

England rules for fire glazing

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Questions from Bristol clients

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Can you add fire-rated zones to existing curtain walling?

Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

Which parts of Bristol do you cover?

All of it: Bristol, the surrounding area and every district in the BS postcode areas.

Related

Related services in Bristol

Process

From enquiry to handover in Bristol

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Measure and check

We measure each opening in Bristol and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.