Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Looking for aluminium fire-rated screens in East Grinstead? We survey, supply and install tested fire-rated glazing for industrial units, hotels and other buildings in and around East Grinstead, including the RH19 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Aluminium fire-rated screens are glazed walls built from aluminium profiles that have been tested with fire-resistant glass and insulating inserts. They suit offices, healthcare and education buildings that want a clean, modern frame matching the rest of the glazing.
Fire-rated aluminium profiles contain insulating and intumescent inserts that standard profiles do not. Swapping in a standard section to save cost removes the rating.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Head details and fixing centres come from the system documentation, especially beneath long-span slabs.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Coverage around East Grinstead includes the RH19 districts and nearby Horley, Crawley, Crowborough. East Grinstead is about 12 km from Crawley, the largest town in our West Sussex coverage.
Every quote in East Grinstead identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover industrial units, hotels and other buildings in East Grinstead.
30 and 60-minute ratings are common, in integrity or insulation classes depending on the glass. We confirm availability for the sizes you need.
Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit East Grinstead to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.