Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in Caterham calls for glazing tested to resist fire, our aluminium fire-rated screens service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Aluminium fire-rated screens are glazed walls built from aluminium profiles that have been tested with fire-resistant glass and insulating inserts. They suit offices, healthcare and education buildings that want a clean, modern frame matching the rest of the glazing.
Coverage around Caterham includes the CR3, RH9, CR6 districts and nearby Coulsdon, Purley, Redhill. Woking, around 34 km from Caterham, is the largest town in the same coverage area.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.
Head details and fixing centres come from the system documentation, especially beneath long-span slabs.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Caterham around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Caterham budgets are not open-ended.
Sector guides below cover hotels, retail and leisure units and other buildings in Caterham.
Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.
Some systems are tested for external use. If the screen forms part of the building envelope we specify an external-rated system and glass.
Survey timing in Caterham depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Caterham and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.