Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Looking for aluminium fire-rated screens in Banstead? We survey, supply and install tested fire-rated glazing for public buildings, blocks of flats and other buildings in and around Banstead, including the SM7 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Aluminium softens at a lower temperature than steel, so fire-rated aluminium systems rely on specific internal inserts, reinforcements and glazing details. We install only the tested system as a whole, in anodised or powder-coated finishes, with doors and side panels where the evidence allows.
We cover Banstead and the surrounding postcode districts, including SM7, SM1, SM2, CR5, SM3, KT20. Nearby towns we also serve include Sutton, Ewell, Epsom. Woking, around 24 km from Banstead, is the largest town in the same coverage area.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Head details and fixing centres come from the system documentation, especially beneath long-span slabs.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
After survey you get a fixed written quote for the agreed scope, so Banstead budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Banstead building has no traceable evidence, we say so and price the options rather than guess.
Aluminium fire-rated screens applies to many building types in Banstead, including public buildings and blocks of flats.
Yes, when it is a system designed and tested for fire. Ordinary aluminium partitions and windows are not fire-rated, however thick the glass.
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Banstead and across Surrey, including the SM7 district and nearby Sutton.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Banstead confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.