Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →If a building in Hythe needs aluminium fire-rated screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Aluminium fire-rated screens are glazed walls built from aluminium profiles that have been tested with fire-resistant glass and insulating inserts. They suit offices, healthcare and education buildings that want a clean, modern frame matching the rest of the glazing.
Aluminium systems are commonly available at 30 and 60 minutes; higher ratings are less common and may point to a steel system instead.
Hinges, locks and closers fitted to doors within the screen must be compatible with the door's evidence.
Some aluminium systems are tested for external facades, others for internal use only. We match the system to the position.
Survey visits can be arranged anywhere in Hythe, including the SO45, SO19 districts, and in nearby Southampton, Totton, Eastleigh. Hythe is about 5 km from Southampton, the largest town in our Hampshire coverage.
If an existing frame in a Hythe building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Hythe budgets are not open-ended.
Every quote in Hythe identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover public buildings, schools and colleges and other buildings in Hythe.
30 and 60-minute ratings are common, in integrity or insulation classes depending on the glass. We confirm availability for the sizes you need.
Usually they can be matched closely in profile and colour so rated and non-rated areas look consistent.
Survey timing in Hythe depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We survey and install in Hythe and across Hampshire, including the SO45 district and nearby Southampton.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Office glass partitions where the wall has to be fire-resisting.
Learn more →Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Hythe and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.