Fire Glazing Surveys
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →When a fire strategy, inspection report or building control comment in Letchworth Garden City calls for glazing tested to resist fire, our fire glazing remedial works service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We work from fire risk assessments, fire door inspection reports and our own surveys, pricing each item clearly and completing the work with photographs and a schedule you can file. Where an item cannot be fixed without evidence from a manufacturer or test body, we say so and set out the options.
Whether the building is in central Letchworth Garden City or the wider SG6, SG15 districts, we can survey and quote. We also cover Hitchin, Stevenage, Luton. Letchworth Garden City lies roughly 38 km from Watford, within our Hertfordshire coverage.
We price each defect separately so you can approve urgent items first.
Remedial glass and seals must suit the existing frame's evidence. Where that evidence is missing, we raise it before work starts.
We plan remedial programmes around residents, pupils or staff, with phasing and clear communication.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can phase work in Letchworth Garden City around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Letchworth Garden City budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can survey and quote for schools and colleges, public buildings and other building types in Letchworth Garden City.
Yes. We prioritise by risk and agree phases with you.
Yes. Send the report and we will price the glazing-related actions item by item.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We survey and install in Letchworth Garden City and across Hertfordshire, including the SG6 district and nearby Hitchin.
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Letchworth Garden City and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.