Fire Glazing Surveys
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Looking for fire glazing remedial works in Stratford? We survey, supply and install tested fire-rated glazing for schools and colleges, healthcare buildings and other buildings in and around Stratford, including the E15 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Fire glazing remedial works are the repairs and replacements that bring glazed fire-resisting elements back into line with their required performance: replacing unsuitable glass, refitting beads and seals, sealing service penetrations, and replacing frames that cannot be shown to be rated.
We plan remedial programmes around residents, pupils or staff, with phasing and clear communication.
Remedial glass and seals must suit the existing frame's evidence. Where that evidence is missing, we raise it before work starts.
Cables and pipes through glazed screens and their surrounds must be fire-stopped with products tested for that application.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Survey visits can be arranged anywhere in Stratford, including the E15, E13, E20, E3, E7, E9 districts, and in nearby Bow, Canning Town, Canary Wharf. Stratford sits within our Greater London coverage, alongside Bow.
After survey you get a fixed written quote for the agreed scope, so Stratford budgets are not open-ended.
We can phase work in Stratford around residents, staff or pupils, with out-of-hours options.
Every quote in Stratford identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for schools and colleges, healthcare buildings and other building types in Stratford.
Yes. Send the report and we will price the glazing-related actions item by item.
Yes, before and after for every item, plus a completion schedule.
Building work in Stratford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Stratford depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Stratford to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.