Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →When a fire strategy, inspection report or building control comment in Morden calls for glazing tested to resist fire, our fire glass replacement service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Broken fire glass replacement is the repair of cracked, shattered or damaged fire-resistant panes with glass of a type the frame's evidence allows, refitted with the correct beads and seals. A cracked fire pane may not perform as tested, so it should be made safe and replaced promptly.
EI glass is laminated to size, so it can take longer to supply than integrity glass. We give you a realistic date.
A broken pane can be a cut hazard and a gap in compartmentation. We can make it safe on the first visit while the replacement is cut.
When the original glass is no longer available, the replacement must be covered by the frame's evidence or an assessment.
Coverage around Morden includes the SM4, SW20, CR4, SW19, KT4, SM5 districts and nearby Mitcham, Wimbledon, Carshalton. Morden sits within our Greater London coverage, alongside Mitcham.
We can phase work in Morden around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Morden identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover hotels, student accommodation and other buildings in Morden.
It may not perform as tested. Treat it as a defect and arrange replacement promptly.
Yes. Single panes can be replaced on their own, provided the replacement is compatible with the frame's evidence.
Building work in Morden follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Morden confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.