Wired Glass Replacement
Replace old Georgian wired glass with modern fire glass.
Learn more →Looking for fire door vision panels in Warwick? We survey, supply and install tested fire-rated glazing for blocks of flats, hotels and other buildings in and around Warwick, including the CV34 postcode district.
Tell us what you need. We reply with next steps and a guide price.
We replace broken, missing and non-compliant vision panels, upgrade old wired glass, and correct beads and seals that have been fitted wrongly. Where a new vision panel is needed, we only cut it in where the door manufacturer or certification scheme allows it.
Missing or wrong glazing seals and loose beads are among the most frequent defects found in fire door inspections. They are quick to fix properly once the door's specification is known.
Old wired glass often provides integrity but not impact safety. Upgrading to modern fire glass with an impact classification removes a common risk in schools and corridors.
We photograph each panel before and after and note the glass marks, so your fire door records stay complete.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Whether the building is in central Warwick or the wider CV34, CV31, CV32 districts, we can survey and quote. We also cover Royal Leamington Spa, Kenilworth, Stratford-upon-Avon. Warwick is about 28 km from Nuneaton, the largest town in our Warwickshire coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Warwick identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Warwick building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover blocks of flats, hotels and other buildings in Warwick.
Not always. Building guidance expects vision panels in doors that subdivide corridors and in double-swing doors, and accessibility guidance favours them in many circulation doors.
Only under the door manufacturer's or certification scheme's instructions. Otherwise the door's rating may no longer be valid.
Building work in Warwick follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replace old Georgian wired glass with modern fire glass.
Learn more →Cracked or broken fire glass replaced to the original specification.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Warwick confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.