Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →We provide fire-rated escape route glazing in Esher and across Surrey, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
We can phase work in Esher around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Esher identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
We plan installation so escape routes stay available while the building is occupied, or agree temporary arrangements with whoever is responsible for fire safety in the building.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Our Surrey coverage takes in Esher (KT10, KT7, KT12, KT8, KT9, TW12) and the neighbouring towns of Walton-on-Thames, Hampton, Sunbury-on-Thames. Esher lies roughly 14 km from Woking, within our Surrey coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover hotels, industrial units and other buildings in Esher.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Yes. We survey and install in Esher and across Surrey, including the KT10 district and nearby Walton-on-Thames.
Building work in Esher follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Esher and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.