Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →Looking for fire-rated escape route glazing in Colchester? We survey, supply and install tested fire-rated glazing for blocks of flats, public buildings and other buildings in and around Colchester, including the CO1 postcode district.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed screens, doors and panels on escape routes in offices, flats, schools and healthcare buildings, working from the fire strategy so integrity and insulation are used in the right places, and smoke control is maintained.
Glazing into a protected stair needs particular care; the rules depend on whether the stair is part of a protected shaft and how the building is used.
In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.
Corridor subdivision doors and double-swing doors normally need vision panels so people do not collide.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Our Essex coverage takes in Colchester (CO1, CO3, CO4, CO2) and the neighbouring towns of Sudbury, Clacton-on-Sea, Witham. Southend-on-Sea, around 41 km from Colchester, is the largest town in the same coverage area.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Colchester identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Colchester budgets are not open-ended.
We can survey and quote for blocks of flats, public buildings and other building types in Colchester.
Yes, if it is fire-rated to the required classification and, for integrity-only glass, within the limits building guidance sets for that position.
Because people escaping may pass right beside the glass. Insulating glass limits the temperature rise on the escape side, so people can pass it more safely.
Yes. We survey and install in Colchester and across Essex, including the CO1 district and nearby Sudbury.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Colchester to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.