Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →We provide fire-rated escape route glazing in Ely and across Cambridgeshire, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Escape route glazing is fire-rated glass in the walls and doors of protected stairs, lobbies and corridors, the routes people rely on to leave a building safely. It has to hold back fire and smoke for the rated time, and on many routes it has to keep heat away from people passing it as well.
In England, blocks of flats over 11 metres need regular checks of communal fire doors, including glazed ones.
Building guidance limits the amount and position of integrity-only glass on protected routes because people may need to pass close to it while fire is on the other side. Insulating glass removes most of those limits.
Doors on escape routes usually need smoke seals as well as fire resistance, so the smoke-control classification matters too.
We cover Ely and the surrounding postcode districts, including CB7, CB6. Nearby towns we also serve include Newmarket, March, Cambridge. Ely is about 40 km from Peterborough, the largest town in our Cambridgeshire coverage.
After survey you get a fixed written quote for the agreed scope, so Ely budgets are not open-ended.
Every quote in Ely identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Ely around residents, staff or pupils, with out-of-hours options.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover public buildings, hotels and other buildings in Ely.
Yes, with phasing and temporary arrangements agreed with whoever is responsible for fire safety in the building.
Doors that subdivide corridors or swing both ways normally do, and the glass must be fire-rated to suit the door.
Survey timing in Ely depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Ely follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Ely and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.