Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For Richmond buildings, we supply, replace and check wired glass replacement wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Wired glass replacement means removing old Georgian or polished wired glass from doors, screens and panels and fitting modern fire-resistant glass that keeps the fire rating while meeting today's impact safety expectations. Wired glass holds together in a fire because of the mesh, but plain wired glass usually lacks an impact safety classification and can cause serious injuries when broken by impact.
We can phase work in Richmond around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Richmond budgets are not open-ended.
Wired glass breaks into sharp pieces held by wire, and the wire weakens the glass. In doors and low-level panels it is a common source of hand and arm injuries.
Doors, side panels and low-level glazing in busy corridors, sports halls and schools are usually replaced first.
Old frames may not have evidence for modern fire glass. We assess them and recommend frame replacement where the evidence cannot be established.
We cover Richmond and the surrounding postcode districts, including TW9, TW10, TW1, TW2, TW8, SW14. Nearby towns we also serve include Isleworth, Hounslow, Barnes. We cover Richmond as part of our Greater London coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for blocks of flats, public buildings and other building types in Richmond.
When broken by impact it can cause serious cuts. That is why it is often replaced in doors and low-level positions.
It can provide integrity in the right frame, typically for 30 minutes and sometimes longer in tested systems, but it does not insulate, and plain wired glass usually lacks an impact safety classification.
Yes. We survey and install in Richmond and across Greater London, including the TW9 district and nearby Isleworth.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Richmond to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.