Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For Gloucester buildings, we supply, replace and check wired glass replacement wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Wired glass replacement means removing old Georgian or polished wired glass from doors, screens and panels and fitting modern fire-resistant glass that keeps the fire rating while meeting today's impact safety expectations. Wired glass holds together in a fire because of the mesh, but plain wired glass usually lacks an impact safety classification and can cause serious injuries when broken by impact.
We can phase work in Gloucester around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Wired glass breaks into sharp pieces held by wire, and the wire weakens the glass. In doors and low-level panels it is a common source of hand and arm injuries.
Doors, side panels and low-level glazing in busy corridors, sports halls and schools are usually replaced first.
Old frames may not have evidence for modern fire glass. We assess them and recommend frame replacement where the evidence cannot be established.
Whether the building is in central Gloucester or the wider GL1, GL2 districts, we can survey and quote. We also cover Cheltenham, Stroud, Tewkesbury. Gloucester is the largest town in our Gloucestershire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Wired glass replacement applies to many building types in Gloucester, including offices and retail and leisure units.
It can provide integrity in the right frame, typically for 30 minutes and sometimes longer in tested systems, but it does not insulate, and plain wired glass usually lacks an impact safety classification.
When broken by impact it can cause serious cuts. That is why it is often replaced in doors and low-level positions.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Gloucester and across Gloucestershire, including the GL1 district and nearby Cheltenham.
Replacement and new vision panels fitted to the door's evidence.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Gloucester to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.