Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Our wired glass replacement service covers Earley and neighbouring areas such as Reading and Wokingham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Schools, hospitals, housing blocks and older offices often still have wired glass in doors and corridors. We survey it, confirm what the frames can accept, and replace it with clear integrity or insulating glass that is compatible with the frame and carries an impact classification.
Survey visits can be arranged anywhere in Earley, including the RG6, RG2, RG41, RG5, RG1 districts, and in nearby Reading, Wokingham, Crowthorne. Earley is about 5 km from Reading, the largest town in our Berkshire coverage.
Modern fire glass is clear, so replacements also improve visibility and appearance.
Wired glass breaks into sharp pieces held by wire, and the wire weakens the glass. In doors and low-level panels it is a common source of hand and arm injuries.
Wired glass generally provides integrity only. Replacing it lets you keep or improve the fire performance while adding impact safety.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
If an existing frame in a Earley building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Earley budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover care homes, schools and colleges and other buildings in Earley.
When broken by impact it can cause serious cuts. That is why it is often replaced in doors and low-level positions.
It can provide integrity in the right frame, typically for 30 minutes and sometimes longer in tested systems, but it does not insulate, and plain wired glass usually lacks an impact safety classification.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Earley follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replacement and new vision panels fitted to the door's evidence.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Earley and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.