Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our integrity fire glass service covers Stoke-on-Trent and neighbouring areas such as Newcastle-under-Lyme and Longton, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Integrity fire glass, classified E, stops flames and hot gases passing for the rated time but does not limit the heat coming through. EW glass adds a cap on the heat radiated through the glass. Both are thinner, lighter and cheaper than fully insulated glass.
Integrity glass costs a fraction of insulated glass and fits slimmer frames, which is why specifying it correctly matters.
E glass gets hot in a fire. Furniture or stored materials beside it can ignite from radiated heat.
Building guidance restricts how much integrity-only glass can be used on protected escape routes and where it can sit. Check the route before choosing E glass.
We cover Stoke-on-Trent and the surrounding postcode districts, including ST4, ST1, ST3, ST2, ST5. Nearby towns we also serve include Newcastle-under-Lyme, Longton, Kidsgrove. Stoke-on-Trent is the main town we cover in Staffordshire.
Every quote in Stoke-on-Trent identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Stoke-on-Trent building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for blocks of flats, healthcare buildings and other building types in Stoke-on-Trent.
Glass that stops flames and hot gases for the rated time but lets heat through. It is classified E.
Yes, considerably, and it is thinner and lighter.
Building work in Stoke-on-Trent follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Stoke-on-Trent and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.