Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our integrity fire glass service covers Bridgend and neighbouring areas such as Maesteg and Tonypandy, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Integrity fire glass, classified E, stops flames and hot gases passing for the rated time but does not limit the heat coming through. EW glass adds a cap on the heat radiated through the glass. Both are thinner, lighter and cheaper than fully insulated glass.
We cover Bridgend and the surrounding postcode districts, including CF31, CF32, CF35. Nearby towns we also serve include Maesteg, Tonypandy, Rhondda. Bridgend is about 19 km from Rhondda, the largest town in our Mid Glamorgan coverage.
Building guidance restricts how much integrity-only glass can be used on protected escape routes and where it can sit. Check the route before choosing E glass.
EW glass limits radiation to 15 kW/m² measured one metre from the glass, reducing the risk of igniting materials or harming people nearby.
Integrity glass costs a fraction of insulated glass and fits slimmer frames, which is why specifying it correctly matters.
Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.
The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.
Every quote in Bridgend identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Bridgend budgets are not open-ended.
We can phase work in Bridgend around residents, staff or pupils, with out-of-hours options.
We can survey and quote for schools and colleges, retail and leisure units and other building types in Bridgend.
In limited amounts and positions. Building guidance sets the rules; insulating glass is used where those limits are exceeded.
Yes, considerably, and it is thinner and lighter.
Bridgend is in Wales, where the Welsh Approved Document B applies to building work and the Regulatory Reform (Fire Safety) Order 2005 covers occupied premises.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Bridgend to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.