Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our integrity fire glass service covers Streatham and neighbouring areas such as Mitcham and Brixton, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
We supply and fit integrity glass in screens, doors, vision panels and windows where the fire strategy allows it, and upgrade to EW or EI where it does not. Choosing correctly between E, EW and EI is where most of the cost on a project is decided.
After survey you get a fixed written quote for the agreed scope, so Streatham budgets are not open-ended.
If an existing frame in a Streatham building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Integrity-only glass may be acceptable in some fire-resisting partitions, screens and doors, often at high level, within the limits national guidance sets. Compartment walls normally need insulating (EI) glazing.
Integrity glass costs a fraction of insulated glass and fits slimmer frames, which is why specifying it correctly matters.
EW glass limits radiation to 15 kW/m² measured one metre from the glass, reducing the risk of igniting materials or harming people nearby.
Survey visits can be arranged anywhere in Streatham, including the SW16, SE27, SW12, SW17, SW2, SE21 districts, and in nearby Mitcham, Brixton, Wimbledon. Streatham sits within our Greater London coverage, alongside Mitcham.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover healthcare buildings, offices and other buildings in Streatham.
Yes, considerably, and it is thinner and lighter.
EW glass also limits heat radiation through the glass, which reduces the risk to people and materials near it.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Streatham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Streatham confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.