Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →When a fire strategy, inspection report or building control comment in Notting Hill calls for glazing tested to resist fire, our integrity fire glass service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Integrity fire glass, classified E, stops flames and hot gases passing for the rated time but does not limit the heat coming through. EW glass adds a cap on the heat radiated through the glass. Both are thinner, lighter and cheaper than fully insulated glass.
Every quote in Notting Hill identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Notting Hill building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
EW glass limits radiation to 15 kW/m² measured one metre from the glass, reducing the risk of igniting materials or harming people nearby.
Integrity glass costs a fraction of insulated glass and fits slimmer frames, which is why specifying it correctly matters.
Building guidance restricts how much integrity-only glass can be used on protected escape routes and where it can sit. Check the route before choosing E glass.
Our Greater London coverage takes in Notting Hill (W11, W2, W8, W12, W10, W14) and the neighbouring towns of Shepherds Bush, Willesden, Fulham. Notting Hill is one of the Greater London districts we cover.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover public buildings, blocks of flats and other buildings in Notting Hill.
In limited amounts and positions. Building guidance sets the rules; insulating glass is used where those limits are exceeded.
EW glass also limits heat radiation through the glass, which reduces the risk to people and materials near it.
Survey timing in Notting Hill depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Notting Hill follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Notting Hill confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.