Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →From the GL50 district outwards, we arrange integrity fire glass for buildings across Cheltenham, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
We supply and fit integrity glass in screens, doors, vision panels and windows where the fire strategy allows it, and upgrade to EW or EI where it does not. Choosing correctly between E, EW and EI is where most of the cost on a project is decided.
Coverage around Cheltenham includes the GL50, GL51, GL52 districts and nearby Tewkesbury, Gloucester, Stroud. Gloucester, around 12 km from Cheltenham, is the largest town in the same coverage area.
Integrity glass costs a fraction of insulated glass and fits slimmer frames, which is why specifying it correctly matters.
Integrity-only glass may be acceptable in some fire-resisting partitions, screens and doors, often at high level, within the limits national guidance sets. Compartment walls normally need insulating (EI) glazing.
EW glass limits radiation to 15 kW/m² measured one metre from the glass, reducing the risk of igniting materials or harming people nearby.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can phase work in Cheltenham around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Cheltenham building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover schools and colleges, retail and leisure units and other buildings in Cheltenham.
In limited amounts and positions. Building guidance sets the rules; insulating glass is used where those limits are exceeded.
Yes, considerably, and it is thinner and lighter.
Survey timing in Cheltenham depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Cheltenham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Cheltenham and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.