Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our insulated fire glass service covers Stafford and neighbouring areas such as Rugeley and Cannock, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We cover Stafford and the surrounding postcode districts, including ST16, ST18. Nearby towns we also serve include Rugeley, Cannock, Burntwood. Stoke-on-Trent, around 23 km from Stafford, is the largest town in the same coverage area.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Stafford budgets are not open-ended.
Every quote in Stafford identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover schools and colleges, care homes and other buildings in Stafford.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.
Building work in Stafford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Stafford to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.