Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →From the S1 district outwards, we arrange insulated fire glass for buildings across Sheffield, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Whether the building is in central Sheffield or the wider S1, S2, S3, S4, S7, S11 districts, we can survey and quote. We also cover Rotherham, Dronfield, Chapeltown. Sheffield is the main town we cover in South Yorkshire.
Every quote in Sheffield identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Sheffield around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Sheffield budgets are not open-ended.
Sector guides below cover schools and colleges, offices and other buildings in Sheffield.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Yes, in normal conditions. It turns opaque only when heated in a fire.
Building work in Sheffield follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Sheffield depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Sheffield and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.