Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →We provide insulated fire glass in Farnworth and across Greater Manchester, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
Whether the building is in central Farnworth or the wider BL4, BL3, M38, BL1, BL11, BL78 districts, we can survey and quote. We also cover Walkden, Bolton, Radcliffe. Farnworth lies roughly 13 km from Manchester, within our Greater Manchester coverage.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Insulating fire glass should be stored dry, upright and away from direct sun before fitting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Farnworth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Farnworth building has no traceable evidence, we say so and price the options rather than guess.
We can survey and quote for industrial units, care homes and other building types in Farnworth.
It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.
The glazing system kept fire on one side (integrity) and limited the temperature rise on the other side (insulation) for at least 60 minutes in a standard fire test.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Farnworth and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.