Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →Our insulated fire glass service covers South Croydon and neighbouring areas such as Croydon and Purley, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
If an existing frame in a South Croydon building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in South Croydon around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
Coverage around South Croydon includes the CR0, CR7, CR9, CR2, CR8, SM6 districts and nearby Croydon, Purley, Wallington. South Croydon sits within our Greater London coverage, alongside Croydon.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Insulated fire glass applies to many building types in South Croydon, including schools and colleges and retail and leisure units.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
Yes, in normal conditions. It turns opaque only when heated in a fire.
Yes. We survey and install in South Croydon and across Greater London, including the CR0 district and nearby Croydon.
Building work in South Croydon follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in South Croydon and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.