Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →We provide insulated fire glass in Brent and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
EI glass is the choice where people need to pass close to the glass during a fire, where combustible materials sit near it, or where building guidance would otherwise restrict glazing. We supply and fit EI 30 to EI 120 glass in tested frames, internally and externally.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Brent building has no traceable evidence, we say so and price the options rather than guess.
We can phase work in Brent around residents, staff or pupils, with out-of-hours options.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
EI testing limits the average temperature rise on the unexposed face to 140°C and any single point to 180°C, which is why people can pass it.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
Survey visits can be arranged anywhere in Brent, including the HA9, HA0, UB6, HA1, W5, NW10 districts, and in nearby Wembley, Harrow, Greenford. Brent is one of the Greater London districts we cover.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for retail and leisure units, blocks of flats and other building types in Brent.
It is a multi-layer product with specialist interlayers, and the frame and installation must suit its weight.
Yes, in normal conditions. It turns opaque only when heated in a fire.
Building work in Brent follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Brent and across Greater London, including the HA9 district and nearby Wembley.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Brent and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.