Fire-Resistant Glass
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →We provide insulated fire glass in Bexley and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Insulated fire glass, classified EI, is glazing that maintains integrity and keeps the temperature rise on the non-fire side within set limits for the rated time. It is usually made of several glass panes bonded with interlayers that foam into an insulating barrier when heated, or with a clear gel that absorbs heat.
Coverage around Bexley includes the DA15, DA5, DA6, DA7, DA14, DA1 districts and nearby Welling, Dartford, Swanley. We cover Bexley as part of our Greater London coverage.
When heated, the interlayers turn opaque and expand, forming an insulating shield. After a fire the glass will need replacing.
Each step up in rating adds layers, so EI 120 is far thicker and heavier than EI 30. The frame has to be designed for it.
Modern EI glass is clear in normal use, with high light transmission at lower ratings.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
If an existing frame in a Bexley building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Bexley identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Bexley budgets are not open-ended.
Sector guides below cover public buildings, retail and leisure units and other buildings in Bexley.
Yes, in normal conditions. It turns opaque only when heated in a fire.
Yes. Once the interlayers have reacted, the glass has done its job and must be replaced.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Survey timing in Bexley depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Integrity and insulating fire glass supplied and fitted into tested frames.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Butt-jointed fire glass walls with minimal frames.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Bexley to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.