Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Fire-rated windows in Newmarket is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated windows are windows tested as complete units to resist fire, needed where an external wall must protect a neighbouring property, where a window looks onto a protected stair or escape route, or where two parts of a building face each other at close range.
Coverage around Newmarket includes the CB8 districts and nearby Haverhill, Ely, Cambridge. Newmarket lies roughly 55 km from Ipswich, within our Suffolk coverage.
Windows used for escape from rooms have their own size and opening rules, and should not be confused with fire-resisting windows.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
If an existing frame in a Newmarket building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Newmarket budgets are not open-ended.
Every quote in Newmarket identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Fire-rated windows applies to many building types in Newmarket, including hotels and public buildings.
No. The frame, glazing system and fixings also need to be part of a tested window.
Usually when a wall is close to a boundary, when a window overlooks a protected escape route, or when part of a building faces another part at close range. Your designer or building control will confirm.
Survey timing in Newmarket depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We survey and install in Newmarket and across Suffolk, including the CB8 district and nearby Haverhill.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Newmarket to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.