Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →When a fire strategy, inspection report or building control comment in Cumbernauld calls for glazing tested to resist fire, our fire-rated windows service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated windows are windows tested as complete units to resist fire, needed where an external wall must protect a neighbouring property, where a window looks onto a protected stair or escape route, or where two parts of a building face each other at close range.
Windows used for escape from rooms have their own size and opening rules, and should not be confused with fire-resisting windows.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
An opening sash introduces gaps and hardware that all need testing. Fixed fire-rated windows are simpler and more widely available.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
Coverage around Cumbernauld includes the G67, G70, G68 districts and nearby Airdrie, Coatbridge, Falkirk. Cumbernauld lies roughly 23 km from East Kilbride, within our Lanarkshire coverage.
We can phase work in Cumbernauld around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Fire-rated windows applies to many building types in Cumbernauld, including public buildings and offices.
Usually when a wall is close to a boundary, when a window overlooks a protected escape route, or when part of a building faces another part at close range. Your designer or building control will confirm.
No. The frame, glazing system and fixings also need to be part of a tested window.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Cumbernauld confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.