Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →Looking for fire-rated windows in Heywood? We survey, supply and install tested fire-rated glazing for industrial units, offices and other buildings in and around Heywood, including the OL10 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Most fire-rated windows are fixed lights, because opening windows need the opening sash, hinges and locks to be tested too. We supply and install fixed and, where tested, opening fire-rated windows in steel, aluminium and timber, matched to the surrounding windows where possible.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
Windows used for escape from rooms have their own size and opening rules, and should not be confused with fire-resisting windows.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
Survey visits can be arranged anywhere in Heywood, including the OL10, OL11, M24 districts, and in nearby Middleton, Rochdale, Bury. Heywood lies roughly 12 km from Manchester, within our Greater Manchester coverage.
After survey you get a fixed written quote for the agreed scope, so Heywood budgets are not open-ended.
Every quote in Heywood identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Heywood building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for industrial units, offices and other building types in Heywood.
No. The frame, glazing system and fixings also need to be part of a tested window.
Frames can be slightly heavier, but most can be finished to match surrounding windows.
Building work in Heywood follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Heywood confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.