Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →From the N7 district outwards, we arrange fire-rated windows for buildings across Holloway, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated windows are windows tested as complete units to resist fire, needed where an external wall must protect a neighbouring property, where a window looks onto a protected stair or escape route, or where two parts of a building face each other at close range.
An opening sash introduces gaps and hardware that all need testing. Fixed fire-rated windows are simpler and more widely available.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
Windows used for escape from rooms have their own size and opening rules, and should not be confused with fire-resisting windows.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Survey visits can be arranged anywhere in Holloway, including the N7, NW5, N19, N5, N4, EC50 districts, and in nearby Highbury, Archway, Camden Town. Holloway is one of the Greater London districts we cover.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Holloway budgets are not open-ended.
If an existing frame in a Holloway building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover public buildings, student accommodation and other buildings in Holloway.
Some can, if the opening version has been tested. Fixed fire-rated windows are more common.
Usually when a wall is close to a boundary, when a window overlooks a protected escape route, or when part of a building faces another part at close range. Your designer or building control will confirm.
Yes. We survey and install in Holloway and across Greater London, including the N7 district and nearby Highbury.
Building work in Holloway follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Holloway and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.