Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →From the CM7 district outwards, we arrange fire-rated windows for buildings across Braintree, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Most fire-rated windows are fixed lights, because opening windows need the opening sash, hinges and locks to be tested too. We supply and install fixed and, where tested, opening fire-rated windows in steel, aluminium and timber, matched to the surrounding windows where possible.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Braintree identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Braintree building has no traceable evidence, we say so and price the options rather than guess.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
Windows used for escape from rooms have their own size and opening rules, and should not be confused with fire-resisting windows.
The closer a wall is to a boundary, the less unprotected area it can have. Fixed windows that meet the wall's full fire-resistance requirement, including insulation where required, are not counted as unprotected area; integrity-only glazing generally still is.
Our Essex coverage takes in Braintree (CM7, CM77) and the neighbouring towns of Witham, Chelmsford, Maldon. Braintree lies roughly 39 km from Southend-on-Sea, within our Essex coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for blocks of flats, public buildings and other building types in Braintree.
Usually when a wall is close to a boundary, when a window overlooks a protected escape route, or when part of a building faces another part at close range. Your designer or building control will confirm.
No. The frame, glazing system and fixings also need to be part of a tested window.
Building work in Braintree follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Braintree depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Braintree confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.