Fire-Rated Curtain Walling
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →If a building in Seaford needs fire-rated windows, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Most fire-rated windows are fixed lights, because opening windows need the opening sash, hinges and locks to be tested too. We supply and install fixed and, where tested, opening fire-rated windows in steel, aluminium and timber, matched to the surrounding windows where possible.
If a fire-rated window cannot open, ventilation may need another route. We coordinate with the designer.
Replacing a non-rated window near a boundary is often triggered by an extension or change of use. We survey the opening before quoting.
Windows used for escape from rooms have their own size and opening rules, and should not be confused with fire-resisting windows.
Survey visits can be arranged anywhere in Seaford, including the BN25 districts, and in nearby Eastbourne, Hailsham, Brighton. Seaford is about 18 km from Brighton, the largest town in our East Sussex coverage.
If an existing frame in a Seaford building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Seaford around residents, staff or pupils, with out-of-hours options.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover blocks of flats, hotels and other buildings in Seaford.
No. The frame, glazing system and fixings also need to be part of a tested window.
Some can, if the opening version has been tested. Fixed fire-rated windows are more common.
Building work in Seaford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Facade glazing tested for fire where boundaries or compartments demand it.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Seaford and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.