Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Our timber fire-rated screens service covers Kirkby-in-Ashfield and neighbouring areas such as Sutton-in-Ashfield and Mansfield, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Paint and stain are fine on the timber, but intumescent seals must stay clear of paint. We mask them during finishing.
Timber screens are tested with specific species and minimum densities. Softwood substitutions or thinner sections can fall outside the evidence.
Heavier insulating glass may need larger sections; we confirm the frame can carry the chosen build-up.
Whether the building is in central Kirkby-in-Ashfield or the wider NG17, NG18 districts, we can survey and quote. We also cover Sutton-in-Ashfield, Mansfield, Hucknall. Kirkby-in-Ashfield lies roughly 17 km from Nottingham, within our Nottinghamshire coverage.
Every quote in Kirkby-in-Ashfield identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Kirkby-in-Ashfield budgets are not open-ended.
If an existing frame in a Kirkby-in-Ashfield building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Timber fire-rated screens applies to many building types in Kirkby-in-Ashfield, including schools and colleges and public buildings.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.
Survey timing in Kirkby-in-Ashfield depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Kirkby-in-Ashfield and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.