Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Looking for timber fire-rated screens in Middleton? We survey, supply and install tested fire-rated glazing for retail and leisure units, public buildings and other buildings in and around Middleton, including the M24 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Timber fire-rated screens are glazed partitions made with hardwood frames, glazing beads and intumescent seals that have been tested together to resist fire. They are common in schools, healthcare, heritage buildings and residential blocks where a warmer finish is wanted.
Heavier insulating glass may need larger sections; we confirm the frame can carry the chosen build-up.
Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.
Timber screens are tested with specific species and minimum densities. Softwood substitutions or thinner sections can fall outside the evidence.
We cover Middleton and the surrounding postcode districts, including M24, M9, OL11, OL10. Nearby towns we also serve include Chadderton, Heywood, Royton. Middleton lies roughly 8 km from Manchester, within our Greater Manchester coverage.
Every quote in Middleton identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Middleton building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Middleton budgets are not open-ended.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover retail and leisure units, public buildings and other buildings in Middleton.
Yes. The timber can be painted, stained or lacquered. Intumescent seals are kept clear of paint.
Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.
Building work in Middleton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Middleton confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.