Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater Manchester · WN2

Hindley timber fire-rated screens

Timber fire-rated screens in Hindley is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.

E 30 – EI 60WN2England

Quote for Hindley

Tell us what you need. We reply with next steps and a guide price.

Timber Fire-Rated Screens in Hindley: what's included

Timber fire-rated screens are glazed partitions made with hardwood frames, glazing beads and intumescent seals that have been tested together to resist fire. They are common in schools, healthcare, heritage buildings and residential blocks where a warmer finish is wanted.

  • Over-panels, side panels and borrowed lights
  • Fire glass with the specified intumescent glazing system
  • Hardwood frames to tested sections and densities
  • Fire-rated timber doorsets set into screens

How we work in Hindley

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Work around occupied buildings

We can phase work in Hindley around residents, staff or pupils, with out-of-hours options.

Before you order timber fire-rated screens: what matters

Heritage buildings

Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.

Moisture and movement

Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.

Beads are part of the rating

Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.

Where we work around Hindley

Survey visits can be arranged anywhere in Hindley, including the WN2, WN3, WN1, BL5 districts, and in nearby Wigan, Westhoughton, Leigh. Hindley lies roughly 24 km from Manchester, within our Greater Manchester coverage.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Building types we cover in Hindley

Timber fire-rated screens applies to many building types in Hindley, including public buildings and blocks of flats.

Questions about timber fire-rated screens in Hindley

Which timbers are used?

Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.

Can you upgrade an old timber screen?

Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.

Which rules apply to fire-rated glazing in Hindley?

Building work in Hindley follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Do you carry out timber fire-rated screens in Hindley?

Yes. We survey and install in Hindley and across Greater Manchester, including the WN2 district and nearby Wigan.

Related

Related services in Hindley

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
to door rating

Fire Door Vision Panels

Replacement and new vision panels fitted to the door's evidence.

Learn more →
Process

What happens next

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Measure and check

We measure each opening in Hindley and check what the existing frames can accept.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote