Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Our timber fire-rated screens service covers Hanworth and neighbouring areas such as Hampton and Feltham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Every quote in Hanworth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Hanworth around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Hanworth building has no traceable evidence, we say so and price the options rather than guess.
Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.
Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.
Paint and stain are fine on the timber, but intumescent seals must stay clear of paint. We mask them during finishing.
Survey visits can be arranged anywhere in Hanworth, including the TW13, TW12, TW14, TW11, TW1, TW2 districts, and in nearby Hampton, Feltham, Sunbury-on-Thames. Hanworth sits within our Greater London coverage, alongside Hampton.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover healthcare buildings, public buildings and other buildings in Hanworth.
Yes. The timber can be painted, stained or lacquered. Intumescent seals are kept clear of paint.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Hanworth follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Hanworth confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.