Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →For Yate buildings, we supply, replace and check timber fire-rated screens wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Yate building has no traceable evidence, we say so and price the options rather than guess.
Heavier insulating glass may need larger sections; we confirm the frame can carry the chosen build-up.
Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.
Paint and stain are fine on the timber, but intumescent seals must stay clear of paint. We mask them during finishing.
Whether the building is in central Yate or the wider BS37 districts, we can survey and quote. We also cover Mangotsfield, Kingswood, Bristol. Yate is about 38 km from Gloucester, the largest town in our Gloucestershire coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for hotels, blocks of flats and other building types in Yate.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
Yes. The timber can be painted, stained or lacquered. Intumescent seals are kept clear of paint.
Building work in Yate follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Yate to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.