Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Gloucestershire · GL1

Timber Fire-Rated Screens for Gloucester buildings

From the GL1 district outwards, we arrange timber fire-rated screens for buildings across Gloucester, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 60GL1England

Quote for Gloucester

Tell us what you need. We reply with next steps and a guide price.

What's involved with timber fire-rated screens in Gloucester

The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.

  • Hardwood frames to tested sections and densities
  • Fire-stopping to the structure
  • Fire-rated timber doorsets set into screens
  • Painted, stained or lacquered finishes

What to check before ordering timber fire-rated screens in Gloucester

Beads are part of the rating

Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.

Heritage buildings

Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.

Species and density count

Timber screens are tested with specific species and minimum densities. Softwood substitutions or thinner sections can fall outside the evidence.

Gloucester coverage and nearby towns

Our Gloucestershire coverage takes in Gloucester (GL1, GL2) and the neighbouring towns of Cheltenham, Stroud, Tewkesbury. Gloucester is the largest town in our Gloucestershire coverage.

What every Gloucester quote includes

Rated systems, not just rated glass

Every quote in Gloucester identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Gloucester budgets are not open-ended.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Building types we cover in Gloucester

We can survey and quote for retail and leisure units, schools and colleges and other building types in Gloucester.

Questions about timber fire-rated screens in Gloucester

Can you upgrade an old timber screen?

Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.

Can timber screens be fire-rated?

Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.

Can you price timber fire-rated screens in Gloucester from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Which rules apply to fire-rated glazing in Gloucester?

Building work in Gloucester follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Gloucester

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
to door rating

Fire Door Vision Panels

Replacement and new vision panels fitted to the door's evidence.

Learn more →
Process

From enquiry to handover in Gloucester

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Gloucester confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote