Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →If a building in Exeter needs timber fire-rated screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Exeter building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Exeter identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.
Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.
Timber screens are tested with specific species and minimum densities. Softwood substitutions or thinner sections can fall outside the evidence.
Coverage around Exeter includes the EX2, EX4, EX1 districts and nearby Exmouth, Tiverton, Newton Abbot. Exeter is about 59 km from Plymouth, the largest town in our Devon coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover schools and colleges, care homes and other buildings in Exeter.
Yes. The timber can be painted, stained or lacquered. Intumescent seals are kept clear of paint.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
Survey timing in Exeter depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Exeter follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Exeter confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.