Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Devon · EX2

Timber Fire-Rated Screens across Exeter

If a building in Exeter needs timber fire-rated screens, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60EX2England

Quote for Exeter

Tell us what you need. We reply with next steps and a guide price.

What's involved with timber fire-rated screens in Exeter

The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.

  • Fire glass with the specified intumescent glazing system
  • Painted, stained or lacquered finishes
  • Hardwood frames to tested sections and densities
  • Fire-rated timber doorsets set into screens

What you can expect in Exeter

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Honest about unknowns

If an existing frame in a Exeter building has no traceable evidence, we say so and price the options rather than guess.

Rated systems, not just rated glass

Every quote in Exeter identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Key checks for Exeter projects

Heritage buildings

Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.

Beads are part of the rating

Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.

Species and density count

Timber screens are tested with specific species and minimum densities. Softwood substitutions or thinner sections can fall outside the evidence.

Where we work around Exeter

Coverage around Exeter includes the EX2, EX4, EX1 districts and nearby Exmouth, Tiverton, Newton Abbot. Exeter is about 59 km from Plymouth, the largest town in our Devon coverage.

Which rules apply to timber fire-rated screens in Exeter?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Exeter building types

Sector guides below cover schools and colleges, care homes and other buildings in Exeter.

FAQs for Exeter

Can timber screens be painted?

Yes. The timber can be painted, stained or lacquered. Intumescent seals are kept clear of paint.

Which timbers are used?

Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.

How quickly can you survey in Exeter?

Survey timing in Exeter depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Which rules apply to fire-rated glazing in Exeter?

Building work in Exeter follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Exeter

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
to door rating

Fire Door Vision Panels

Replacement and new vision panels fitted to the door's evidence.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Site visit

A survey in Exeter confirms sizes, access, existing evidence and fixing conditions.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote