Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
County Down · BT22

Newtownards timber fire-rated screens

Timber fire-rated screens in Newtownards is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.

E 30 – EI 60BT22Northern Ireland

Quote for Newtownards

Tell us what you need. We reply with next steps and a guide price.

What's involved with timber fire-rated screens in Newtownards

The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.

  • Over-panels, side panels and borrowed lights
  • Fire-rated timber doorsets set into screens
  • Hardwood frames to tested sections and densities
  • Fire-stopping to the structure

What to check before ordering timber fire-rated screens in Newtownards

Beads are part of the rating

Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.

Finishing

Paint and stain are fine on the timber, but intumescent seals must stay clear of paint. We mask them during finishing.

Moisture and movement

Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.

Where we work around Newtownards

Coverage around Newtownards includes the BT22, BT23 districts and nearby Bangor, Belfast, Carrickfergus. Newtownards lies roughly 8 km from Bangor, within our County Down coverage.

What you can expect in Newtownards

Rated systems, not just rated glass

Every quote in Newtownards identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Newtownards budgets are not open-ended.

Northern Ireland rules applied

Designs follow the building and fire safety rules that apply in Northern Ireland, not a one-size-fits-all approach.

Fire glazing rules in Northern Ireland

Northern Ireland Which rules apply?

In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.

Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.

Newtownards building types

Timber fire-rated screens applies to many building types in Newtownards, including retail and leisure units and public buildings.

FAQs for Newtownards

Can you upgrade an old timber screen?

Sometimes. If the frame can be shown to be suitable, we can replace non-rated glass and add the correct seals and beads. Where it cannot, replacement is the honest answer.

Can timber screens be fire-rated?

Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.

Can you price timber fire-rated screens in Newtownards from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

How quickly can you survey in Newtownards?

Survey timing in Newtownards depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Related

Related services in Newtownards

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
to door rating

Fire Door Vision Panels

Replacement and new vision panels fitted to the door's evidence.

Learn more →
Process

From enquiry to handover in Newtownards

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Newtownards to measure, record existing marks and check the frames and substrate.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote