Fanlights, Side Panels & Borrowed Lights
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →When a fire strategy, inspection report or building control comment in Kilmarnock calls for glazing tested to resist fire, our timber fire-rated screens service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
The rating depends on the timber species and density, frame sections, bead profiles, fixings and the glazing seals used in the test. We build timber screens to a tested specification, or to a formal assessment, and finish them without compromising the intumescent details.
Every quote in Kilmarnock identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Kilmarnock building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
Timber suits listed and older buildings, and existing screens can sometimes be upgraded with new glass and seals, subject to an assessment of the frame.
Bead profile, height and fixing type and spacing are all taken from the test. Short-cutting the fixings is a common reason screens fail inspection.
Timber frames need dry conditions on site and acclimatisation before glazing to avoid movement around the glass.
Survey visits can be arranged anywhere in Kilmarnock, including the KA3 districts, and in nearby Irvine, Ayr, Newton Mearns. Kilmarnock is the main town we cover in Ayrshire.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
We can survey and quote for industrial units, schools and colleges and other building types in Kilmarnock.
Dense hardwoods are typical; the exact species depends on the tested specification. We confirm species and density on the drawings.
Yes. Hardwood screens are tested to 30 and 60 minutes in many configurations, with the right glass, beads and seals.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Kilmarnock and across Ayrshire, including the KA3 district and nearby Irvine.
Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Replacement and new vision panels fitted to the door's evidence.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Kilmarnock and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.