Fire-Rated Glazed Screens
Internal glazed screens that keep compartments and corridors protected.
Learn more →When a fire strategy, inspection report or building control comment in Aldridge calls for glazing tested to resist fire, our steel fire-rated screens service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We supply and install tested steel screen systems in black, RAL colours and industrial finishes, including the gridded warehouse look, with integrated single and double doors. Each screen is drawn up within its system evidence so the appearance does not come at the cost of the rating.
If an existing frame in a Aldridge building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Aldridge identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Decorative steel-look aluminium or slim steel partitions sold for offices are not automatically fire-rated. We only fit systems with test or assessment evidence for the classification you need.
Steel systems are fabricated to measure, so allow for survey, drawings, approval and fabrication before the fit date.
Where steel glazing forms an external wall, thermal performance and condensation need designing in as well as the fire rating.
Our West Midlands coverage takes in Aldridge (WS9, WS4, WS8, B74) and the neighbouring towns of Walsall, Bloxwich, Sutton Coldfield. Aldridge lies roughly 14 km from Birmingham, within our West Midlands coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover blocks of flats, public buildings and other buildings in Aldridge.
Some steel systems with that look are tested for fire, many decorative ones are not. Ask for the classification and test evidence; we only quote tested systems for fire-rated positions.
Yes. Single, double and in some systems sliding doors can be built into the screen, provided the combination is covered by the evidence.
Yes. We survey and install in Aldridge and across West Midlands, including the WS9 district and nearby Walsall.
Building work in Aldridge follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Aldridge to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.