Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Oxfordshire · OX1

Oxford fire-rated glazed screens

From the OX1 district outwards, we arrange fire-rated glazed screens for buildings across Oxford, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 120OX1England

Quote for Oxford

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Oxford: what's included

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Handover evidence pack
  • Survey and setting-out against the fire strategy drawings
  • Fire-stopping at head, jambs and sill to the system details
  • Integrity or insulating glass to the required classification

Key checks for Oxford projects

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

Integrity-only screens on escape routes

Building guidance limits where integrity-only glazing can sit on protected escape routes, and in some positions restricts it to above a set height from the floor. Insulating screens are not restricted in the same way, so the route plan often decides the glass.

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Which rules apply to fire-rated glazed screens in Oxford?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Oxford coverage and nearby towns

Survey visits can be arranged anywhere in Oxford, including the OX1, OX2, OX4, OX3 districts, and in nearby Abingdon, Didcot, Witney. Oxford is the largest town in our Oxfordshire coverage.

What every Oxford quote includes

Work around occupied buildings

We can phase work in Oxford around residents, staff or pupils, with out-of-hours options.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Oxford budgets are not open-ended.

Honest about unknowns

If an existing frame in a Oxford building has no traceable evidence, we say so and price the options rather than guess.

Building types we cover in Oxford

Fire-rated glazed screens applies to many building types in Oxford, including schools and colleges and student accommodation.

FAQs for Oxford

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

How quickly can you survey in Oxford?

Survey timing in Oxford depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.

Which rules apply to fire-rated glazing in Oxford?

Building work in Oxford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Oxford

Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Oxford to measure, record existing marks and check the frames and substrate.

Quote and evidence

Your quote lists each item with its classification and the evidence it relies on.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote