Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Hertfordshire · SG13

Fire-Rated Glazed Screens — Hertford and SG13

Our fire-rated glazed screens service covers Hertford and neighbouring areas such as Hoddesdon and Welwyn Garden City, with every job built around a tested system.

E 30 – EI 120SG13England

Quote for Hertford

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Hertford: what's included

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Survey and setting-out against the fire strategy drawings
  • Integrated fire doors and glazed doorsets
  • Fire-stopping at head, jambs and sill to the system details
  • Steel, aluminium, timber or frameless frame systems

Before you order fire-rated glazed screens: what matters

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Acoustic and security needs

Fire glass can be combined with acoustic or security performance in many systems. We confirm the combined build-up is covered before pricing it.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Where we work around Hertford

Whether the building is in central Hertford or the wider SG13, SG14 districts, we can survey and quote. We also cover Hoddesdon, Welwyn Garden City, Hatfield. Hertford lies roughly 27 km from Watford, within our Hertfordshire coverage.

What every Hertford quote includes

Rated systems, not just rated glass

Every quote in Hertford identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Work around occupied buildings

We can phase work in Hertford around residents, staff or pupils, with out-of-hours options.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Building types we cover in Hertford

Fire-rated glazed screens applies to many building types in Hertford, including blocks of flats and public buildings.

FAQs for Hertford

Do fire-rated screens need maintenance?

They need periodic checks for damaged glass, missing beads, failed seals and unauthorised changes such as new cable holes. We can carry out these checks as part of a survey.

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Do you carry out fire-rated glazed screens in Hertford?

Yes. We survey and install in Hertford and across Hertfordshire, including the SG13 district and nearby Hoddesdon.

Which rules apply to fire-rated glazing in Hertford?

Building work in Hertford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Hertford

Process

From enquiry to handover in Hertford

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Hertford confirms sizes, access, existing evidence and fixing conditions.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote