Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · UB5

Fire-Rated Glazed Screens in Northolt

Our fire-rated glazed screens service covers Northolt and neighbouring areas such as Greenford and Harrow, with every job built around a tested system.

E 30 – EI 120UB5England

Quote for Northolt

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Northolt: what's included

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Integrated fire doors and glazed doorsets
  • Steel, aluminium, timber or frameless frame systems
  • Survey and setting-out against the fire strategy drawings
  • Integrity or insulating glass to the required classification

What every Northolt quote includes

Work around occupied buildings

We can phase work in Northolt around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Northolt identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Before you order fire-rated glazed screens: what matters

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Building control

New screens, and changes to existing fire-resisting walls, are normally building work. We provide the product evidence your building control body or approved inspector will ask for.

Doors inside a screen

A door in a glazed screen has to be tested in that configuration or covered by a doorset certificate and an assessment for the screen. We specify the door and screen as one system rather than mixing products.

Areas we cover around Northolt

We cover Northolt and the surrounding postcode districts, including UB5, UB6, UB4, HA1, HA0, UB1. Nearby towns we also serve include Greenford, Harrow, Southall. Northolt is one of the Greater London districts we cover.

Which rules apply to fire-rated glazed screens in Northolt?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

Building types we cover in Northolt

Sector guides below cover schools and colleges, retail and leisure units and other buildings in Northolt.

Questions about fire-rated glazed screens in Northolt

How large can a fire-rated glazed screen be?

It depends on the system's evidence. Most systems state maximum pane sizes and overall heights; very tall or wide screens may need an assessment from a test body. We confirm the limits during design.

How long does installation take?

Small screens are often fitted in a day once manufactured. Larger runs depend on site access and phasing; we agree a programme with you when we quote.

Do you work on occupied buildings in Northolt?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Northolt?

Building work in Northolt follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Northolt

Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Northolt to measure, record existing marks and check the frames and substrate.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote