Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
County Londonderry · BT47

Fire-Rated Glazed Screens across Derry / Londonderry

From the BT47 district outwards, we arrange fire-rated glazed screens for buildings across Derry / Londonderry, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 120BT47Northern Ireland

Quote for Derry / Londonderry

Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Glazed Screens in Derry / Londonderry: what's included

We design, supply and install fire-rated screens in steel, aluminium, timber and frameless formats, working from the rating and positions on your fire strategy. Every screen is built within the limits of its test or assessment evidence: pane sizes, transom and mullion spacing, glass type and the way it is fixed to the surrounding structure.

  • Survey and setting-out against the fire strategy drawings
  • Handover evidence pack
  • Integrated fire doors and glazed doorsets
  • Fire-stopping at head, jambs and sill to the system details

What you can expect in Derry / Londonderry

Rated systems, not just rated glass

Every quote in Derry / Londonderry identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Northern Ireland rules applied

Designs follow the building and fire safety rules that apply in Northern Ireland, not a one-size-fits-all approach.

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

What to check before ordering fire-rated glazed screens in Derry / Londonderry

Integrity-only screens on escape routes

Building guidance limits where integrity-only glazing can sit on protected escape routes, and in some positions restricts it to above a set height from the floor. Insulating screens are not restricted in the same way, so the route plan often decides the glass.

What the screen is fixed to matters

Test evidence covers the screen's connection to specific supporting constructions, such as masonry, concrete or a tested partition. Fixing into a lightweight wall that is not covered can undermine the rating, so we check the substrate first.

Movement and deflection

Long screens under slabs need deflection heads so floor movement does not crack the glass or open gaps. The head detail has to come from the same evidence as the rest of the screen.

Areas we cover around Derry / Londonderry

Coverage around Derry / Londonderry includes the BT47, BT48 districts and nearby Coleraine, Omagh, Ballymena. Derry / Londonderry is the main town we cover in County Londonderry.

Which rules apply to fire-rated glazed screens in Derry / Londonderry?

Northern Ireland Which rules apply?

In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.

Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.

Sectors we cover in Derry / Londonderry

Fire-rated glazed screens applies to many building types in Derry / Londonderry, including care homes and retail and leisure units.

Questions about fire-rated glazed screens in Derry / Londonderry

Can you add a screen to an occupied building?

Yes. We plan dust control, out-of-hours working and temporary protection so the building can stay in use where the fire strategy allows.

Can a fire-rated screen be fully glazed?

Yes. Many screens are glazed from floor to ceiling, subject to the classification needed on that route and any impact safety requirements at low level.

Do you carry out fire-rated glazed screens in Derry / Londonderry?

Yes. We survey and install in Derry / Londonderry and across County Londonderry, including the BT47 district and nearby Coleraine.

Which rules apply to fire-rated glazing in Derry / Londonderry?

Derry / Londonderry is in Northern Ireland, where the Building Regulations (NI) 2012 and Technical Booklet E apply, with the Fire Safety Regulations (NI) 2010 covering occupied premises.

Related

Related services in Derry / Londonderry

Process

What happens next

Share the details

Send the fire strategy extract, inspection report or a few photos of the openings.

Survey

We visit Derry / Londonderry to measure, record existing marks and check the frames and substrate.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote