Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For Crawley buildings, we supply, replace and check fire-rated glazed doors wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
Residential blocks in England over 11 metres need regular fire door checks under the Fire Safety (England) Regulations 2022; glazed doors are included.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Self-closing devices and correct gaps are part of the performance. We set them at installation and record them.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Survey visits can be arranged anywhere in Crawley, including the RH11, RH10 districts, and in nearby Horley, Horsham, East Grinstead. Crawley is the main town we cover in West Sussex.
If an existing frame in a Crawley building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Crawley budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Sector guides below cover public buildings, industrial units and other buildings in Crawley.
Cutting new apertures into a fire door is only acceptable when done under the door manufacturer's or certification scheme's instructions. Often a new doorset is the safer answer.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Building work in Crawley follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Crawley confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.