Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For Chelsea buildings, we supply, replace and check fire-rated glazed doors wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
Survey visits can be arranged anywhere in Chelsea, including the SW10, SW3, SW7, SW1X, SW5, W1M districts, and in nearby Battersea, Fulham, Pimlico. We cover Chelsea as part of our Greater London coverage.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Self-closing devices and correct gaps are part of the performance. We set them at installation and record them.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can phase work in Chelsea around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Chelsea budgets are not open-ended.
If an existing frame in a Chelsea building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover schools and colleges, retail and leisure units and other buildings in Chelsea.
Cutting new apertures into a fire door is only acceptable when done under the door manufacturer's or certification scheme's instructions. Often a new doorset is the safer answer.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Yes. We survey and install in Chelsea and across Greater London, including the SW10 district and nearby Battersea.
Survey timing in Chelsea depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Chelsea and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.